3.

Replacing the Units

(1)

Replacing the Image Transfer Roller Unit

Removal Procedure
NOTES
• If a Finishing Option is installed, remove if from the main unit before trying to replace the
Waste Toner Bottle.
• When removing the Finishing Option, support the horizontal transport unit with your hand
to prevent if from dropping.
Reinstallation Procedure
1. Turn OFF the main switch.
2. Open the Right Door.
4025E018AA
3. Unlock the blue lock levers (at two places).
4. Holding onto the blue lock levers (at two places),
remove the Image Transfer Roller Unit.
4025E019AB
1. Holding onto the blue lock levers (at two places),
mount the Image Transfer Roller Unit.
2. Lock the blue lock levers (at two places).
NOTE
• Avoid touching the Transfer Roller surface as it
may become damaged.
4025E020AB
3. Close the Right Door.
NOTE
• Make sure that the door is locked in position both
at front and rear.
4. Turn ON the Power Switch.
5. Select "Tech. Rep. Mode"
4025E021AA
and clear the count of "Transfer Roller Unit."