3-3.
ELECTRICAL/IMAGE ADJUSTMENT
(1)
Accessing the Tech. Rep. Mode
1. Press the Utility key.
2. Touch [Meter Count].
3. Press the following keys in this order:
Stop → 0 → 0 → Stop → 0 → 1
NOTE
• Ensure appropriate security for Tech. Rep. mode setting procedures. They should
NEVER be shown to any unauthorized person not involved with service jobs.
(2)
Producing a Test Print
1. Call the Tech. Rep. Mode to the screen.
2. Touch [Test Print].
3. Select the desired test pattern type.
4. Make the necessary settings.
5. Press the Start key.
D-45