(80) C13D1: Cyan IU EEPROM access error
(81) C13D2: Magenta IU EEPROM access error
(82) C13D3: Yellow IU EEPROM access error
(83) C13D4: Black IU EEPROM access error
<Detection Timing>
Malfunction Code
C13D1
C13D2
C13D3
C13D4
<Action>
IO Board (PWB-IO)
Step
Action
Clean the connection between
1
the IU and copier if dirty.
2
Reinstall IU C/M/Y/Bk.
3
Change IU C/M/Y/Bk.
4
Change PWB-IO.
Setting 1 "Start Flag" of GA register does not become ready even
after the lapse of a predetermined period of time after a cyan IU
EEPROM access control has been executed.
Setting 1 "Start Flag" of GA register does not become ready even
after the lapse of a predetermined period of time after a magenta
IU EEPROM access control has been executed.
Setting 1 "Start Flag" of GA register does not become ready even
after the lapse of a predetermined period of time after a yellow IU
EEPROM access control has been executed.
Setting 1 "Start Flag" of GA register does not become ready even
after the lapse of a predetermined period of time after a black IU
EEPROM access control has been executed.
Relevant Electrical Parts
IU C/M/Y/Bk
Ref.
Page
—
—
—
—
T-65
Description
WIRING DIAGRAM
Control Signal
—
—
—
—
Location
(Electrical
Component)
—
—
—
—