C3310: Ccd Clamp/Gain Adjustment Failure - Minolta CF2002 Service Manual

Hide thumbs Also See for CF2002:
Table of Contents

Advertisement

(88) C3310: CCD clamp/gain adjustment failure

<Detection Timing>
Malfunction Code
C3310
<Action>
Scanner Assy
Step
Action
Correct the harness connec-
1
tion between PWB-A and
PWB-C if faulty.
Check for possible extraneous
2
light and correct as necessary.
Clean the lens, mirrors, CCD
3
surface, and shading sheet if
dirty.
Correct reflective mirror of the
4
Scanner if faulty, or change
Scanner.
5
Change PWB-A.
6
Change PWB-C.
• The adjustment value is 0 or 255 during a CCD clamp adjust-
ment.
• The peak value of the output data is 64 or less during a CCD
gain adjustment.
Relevant Electrical Parts
CCD Sensor Board (PWB-A)
Image Processing Board (PWB-C)
Ref.
Page
T-67
Description
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)