Minolta CF2002 Service Manual page 164

Hide thumbs Also See for CF2002:
Table of Contents

Advertisement

Counter
• To clear the counts of two or more counters within a group or across different groups at
once, touch "Counter Reset," select the specific counters to be cleared, and touch "END."
Two or more counters can be selected.
Item
Purpose
To check the
• To clear the count of a counter, select the specific part and press
number of
hours or
• If a counter is cleared mistakenly, press the Interrupt key, which will
times each
of the differ-
• It is not possible to clear the count of the counters for the Fusing
ent mainte-
nance parts
<1>
has been
• Fusing Unit: Number of times a sheet of paper is fed through
used or to
• Transfer Roller Unit: Number of times a sheet of paper is fed
clear the
count of
• Transfer Belt Unit: Number of times a sheet of paper is fed through
each

counter.
When

each of
• Paper Powder Filter/Ozone Filter: Number of times a sheet of paper
the main-
tenance
• 1st.: Number of sheets of paper fed from the 1st Drawer
parts is
• 2nd.: Number of sheets of paper fed from the 2nd Drawer
replaced.
• 3rd.: Number of sheets of paper fed from the 3rd Drawer
• 4th.: Number of sheets of paper fed from the 4th Drawer
<2>
• Cyan IU: Period of time over which the Cyan Developing Unit has
Life
• Magenta IU: Period of time over which the Magenta Developing
• Yellow IU: Period of time over which the Yellow Developing Unit has
• Black IU: Period of time over which the Black Developing Unit has

• LCC Parts 1: Number of sheets of paper fed from the LCC
• LCC Parts 2: Number of sheets of paper fed from the LCC
• ADF Feed: Number of sheets of paper fed through the take-up sec-
• ADF Rev.: Number of sheets of paper fed through the turnover unit
• Sorter/Finisher: Number of sheets of paper fed out of the Sorter/
• Staple: Number of stapling sequences performed
• Punch: Number of hole-punch sequences performed
• Paper Fold: Number of folding sequences performed
Setting/Precautions
the Clear key.
undo the clearing operation.
Unit and IU, which are provided with a new unit detection function.
through
The number of copies made (A) is compared with the number of
hours through which the unit has been energized translated to the
equivalent number of copies made (B) and (A) or (B), whichever
reaches the life value, is detected.
is fed through
been used.
Unit has been used.
been used.
been used.
The period of time over which the PC Drum has been turned (A) is
compared with the period of time over which the Developing Roller
has been rotated translated to the period of time over which the PC
Drum has been turned (B) and (A) or (B), whichever reaches the life
value, is detected.
tion of the ADF
of the ADF
Finisher
S-31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cf3102

Table of Contents