Minolta CF2002 Service Manual page 32

Hide thumbs Also See for CF2002:
Table of Contents

Advertisement

PM Parts
Imaging Unit C/M/Y
Imaging Unit Bk
Ozone Filter
Comb electrode
LPH Assy
Fusing Unit
Fusing Entrance
Guide Plate
Deodorant Filter
NOTES
• Replace the Paper Take-Up Roller and Separator Roller at the same time.
• Replace the Paper Dust Remover and Ozone Filter at the same time.
• When the Black Imaging Unit is replaced, also replace the Deodorant Filter (packed with
the Black Imaging Unit) at the same time.
• When the Toner Cartridge is replaced, also clean the Comb electrode.
• The numeric values in the Maintenance Cycle column represent the Life Counter values.
• The contents of this maintenance schedule are subject to change without notice.
Maintenance Cycle
Clean
Replace
52 K
82 K
152 K
10 K or
When image
failure occurs
Upon each call
or replacement
of IU
152 K
When
malfunction
occurs
10 K
E-2
Ref. Page
Parts No.
4025-0447-01
4588-510 (100 V)
4588-512 (230 V)
4588-513 (120 V)
4588-711
in This
Manual
E-22
 
E-15
 
E-15
 
E-16
 
E-26
 
E-17
 
E-17
 

Advertisement