(9)
IR System: distorted image
<Troubleshooting Procedure>
Section
Step
Installation
1
IR is installed on a level sur-
face if mounted without any
rack.
Rack is installed on a level sur-
face.
The Rack is tilted with a lot of
play.
2nd/3rd
2
Scanner Assy is not properly
Mirrors Car-
aligned with 2nd/3rd Mirrors
riage
Carriage.
Scanner
3
Scanner Motor turns smoothly.
Motor
4
The problem has been elimi-
nated through the checks of
steps up to 3.
<Typical Faulty Image>
ABCDE
ABCDE
ABCDE
ABCDE
ABCDE
4011T045AA
Check Item
Result
T-83
Action
NO
Reinstall.
NO
Reinstall.
YES
Adjust rack leg height.
YES
Readjust with the Scanner/
Mirrors Carriage Positioning
Jigs.
NO
Change belt.
Change Scanner Motor.
NO
Change Scanner Assy.
Change CCD Unit.