C0096: Image Transfer Belt Pressure/Retraction Failure - Minolta CF2002 Service Manual

Hide thumbs Also See for CF2002:
Table of Contents

Advertisement

(22) C0096: Image Transfer Belt pressure/retraction failure

<Detection Timing>
Malfunction Code
C0096
<Action>
1st Image Transfer Retraction Position
Sensor (PC28)
1st Image Transfer Pressure/Retraction
Motor (M11)
Step
Action
Check the M11 connector for
1
proper connection and correct
as necessary.
2
PC28 I/O check
3
M11 operation check
4
Change PWB-IO.
• The 1st Image Transfer Retraction Position Sensor is not acti-
vated (retracted position) within 3 sec. after the 1st Image Trans-
fer Pressure/Retraction Motor has started turning during a
sequence of the Transfer Belt's retracting motion.
• The 1st Image Transfer Retraction Position Sensor is not deacti-
vated (pressed position) within 1 sec. after the 1st Image Trans-
fer Pressure/Retraction Motor has started turning during a
sequence of the Transfer Belt's pressing motion.
Relevant Electrical Parts
Ref.
Page
T-4 to
T-10
T-3
T-44
Description
IO Board (PWB-IO)
WIRING DIAGRAM
Control Signal
PWB-IO PJ16IO-1 to 4
(Pulse Output)
Location
(Electrical
Component)
5-E
5-D