IR System: skewed image
<Troubleshooting Procedure>
Section
Step
Original
1
Original is skew.
Original
2
Original Glass is in positive
Glass
contact with the flat spring
without being tilt.
2nd/3rd
3
Scanner Assy is not properly
Mirrors Car-
aligned with 2nd/3rd Mirrors
riage
Carriage.
4
The problem has been elimi-
nated through the checks of
steps up to 3.
<Typical Faulty Image>
4011T048AA
Check Item
T-82
Result
Action
YES
Reposition original.
NO
Reinstall the glass. Check the
original loading position.
YES
Readjust with the Scanner/
Mirrors Carriage Positioning
Jigs.
NO
Change Scanner Assy.
Change CCD Unit.