Fujitsu PRIMEQUEST 2000 Series Message Reference page 97

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
Adapter error (Error receiving msg from VF)
Meaning:
Messages from the VF cannot be received.
Corrective action:
High probability of an adapter failure. Proceed to adapter replacement
Severity:
Warning
11834
Adapter error (Network adapter has over heated)
Meaning:
The adapter has stopped because of overheating. Restart (reset) the adapter.
If the problem persists even after an adapter restart, power off the system, and replace the adapter.
Corrective action:
High probability of an adapter failure. Proceed to adapter replacement
Severity:
Warning
11836
Adapter error (should not be a VF)
Meaning:
The ID assigned to the PF should be assigned to the VF.
Corrective action:
High probability of an adapter failure. Proceed to adapter replacement
Severity:
Warning
■FC (Linux) related
12005
Device or FC-Network error (Nodev timeout)
Meaning:
The driver lost the connection destination(A device lost time-out occurred).
Corrective action:
Check the connection path (cable, switch, HBA, disk device port, etc.). If the error keeps recurring, contact
your sales representative or a field engineer.
Severity:
Warning
12015
Adapter error (stray mailbox interrupt mbxCommand)
Meaning:
The completion of a mailbox command that had supposedly not been issued was reported.
Corrective action:
Hardware or firmware has a fault. If the error keeps recurring, contact your sales representative or a field
engineer.
Severity:
Warning
12016
Adapter error (CONFIG_LINK mbxStatus Error)
Meaning:
A CONFIG_LINK mailbox command was issued, but it failed.
Corrective action:
Hardware or firmware has a fault. If the error keeps recurring, contact your sales representative or a field
engineer.
Severity:
Warning