Fujitsu PRIMEQUEST 2000 Series Message Reference page 117

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
An error occurred in the device configuration. The number of LUNs reported by the device exceeds the
supported limit of the operating system.
Corrective action:
Reduce the number of LUNs on the device side.
Severity:
Warning
14072
Device error (Device configuration error)
Meaning:
An error occurred in the device configuration.
Corrective action:
If you need to use all LUNs, the external disk unit configuration must be changed. If you accept the fact that
some of them will not be available, no action is necessary.
Severity:
Warning
14073
Device error (Unexpected response)
Meaning:
A SCSI device scan was interrupted. The interrupt reason is displayed individually before this message.
Corrective action:
Some devices were not recognized. Eliminate the cause. Then, perform a reboot.
Severity:
Warning
14116
Device error (too big for this kernel)
Meaning:
The size of a block exceeds the allowable limit supported by the kernel.
Corrective action:
If a single drive is used, replace the disk. If an external disk unit is used, examine it.
Severity:
Warning
14131
Device error (Can't create sysfs link from SCSI device)
Meaning:
The configuration of a device is incorrect.
Corrective action:
Specify the configuration of the device correctly, and try again.
Severity:
Warning
14138
Device error (Volume overflow. CDB)
Meaning:
Data that could not be written to a device because it was full is left in a buffer. An I/O request sent to the
SCSI device was rejected.
Corrective action:
Identify the type of the target device from its host, id, and lun. Then, check the sense key (extended sense)
to determine the corrective action.
1 (Recovered Error): If it is a removable device, perform cleaning.
2 (Not Ready): If it is non-removable, replace the device.
3 (Medium Error): If it is a disk, replace the device. If it has removable media, perform cleaning and replace
the media.
4 (Hard Error): Replace the device.
5 (Illegal Request): Examine the software.
6 (Unit Attention): This is notification information from various devices. (e.g., reset status, RAID degradation
if applicable)
101
C122-E178-02EN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents