Fujitsu PRIMEQUEST 2000 Series Message Reference page 118

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
7 (Data Protect): Check the Write Protect status.
8 (Blank Check): Check tape and other operations.
9 (Aborted Command): Investigate problems in the SCSI bus and FC transmission paths.
Severity:
Warning
14139
Device error (I/O error)
Meaning:
An I/O error occurred.
Corrective action:
If the return code is "0x00010000" a no-response error occurred on the disk. Replace the disk.
If another return code is returned, identify the type of the target device from its host, id, and lun. Then, check
the sense key (extended sense) to determine the corrective action.
1 (Recovered Error): If it is a removable device, perform cleaning.
2 (Not Ready): If it is non-removable, replace the device.
3 (Medium Error): If it is a disk, replace the device. If it has removable media, perform cleaning and replace
the media.
4 (Hard Error): Replace the device.
5 (Illegal Request): Examine the software.
6 (Unit Attention): This is notification information from various devices. (e.g., reset status, RAID degradation
if applicable)
7 (Data Protect): Check the Write Protect status.
8 (Blank Check): Check tape and other operations.
9 (Aborted Command): Investigate problems in the SCSI bus and FC transmission paths.
Severity:
Warning
14165
Device error
Meaning:
A No Sense error occurred in the device. The return value from the HBA is displayed as is.
Corrective action:
Check the sense key included in the message. Take corrective action as described below, according to the
character string of the sense key.
- For "No Sense," "Recovered Error," or "Unit Attention":
>> If the error occurred alone, no action is necessary. If the error has occurred repeatedly, collect the data
for investigation (dump or fjsnap), and contact your sales representative or a field engineer.
- For "Medium Error":
>> Replace the disk or tape.
- For "Blank Check":
>> Check the read and write operations of the disk or tape. If there is no problem in operations, collect the
data for investigation (dump or fjsnap), and contact your sales representative or a field engineer.
- Other
>> Collect the data for investigation (dump or fjsnap). Contact your sales representative or a field engineer.
Severity:
Warning
■MPD (Linux) related
15039
Adapter or Device or FC-Network error (MPD detected event)
Meaning:
The multipath driver detected an I/O or FC multipath configuration error.
Corrective action:
Take corrective action according to the messages that the multipath driver outputs and the instructions in the
ETERNUS Multipath Driver User's Guide.
Severity:
Warning
102
C122-E178-02EN