MMB Messages
086F03FF
Power Supply input lost
Meaning:
Power failure was detected.
Corrective action:
Check the input power of the target PSU and IO_PSU.
Severity:
Error
086F05FF
Power Supply input out-of-range, but present
Meaning:
100V/200V AC cable connection is incorrect.
Corrective action:
Check the AC cable connection.
Severity:
Error
086F0601
Configuration error
Meaning:
PSU with incorrect specifications is mounted, or different types of PSUs are mixed.
Corrective action:
Replace with the appropriate PSU.
Severity:
Error
086F0602
Configuration error in excess unit
Meaning:
PSU mounting location is wrong.
Corrective action:
Check the PSU mounting location.
Severity:
Error
08EF00FF
Removed
Meaning:
The PSU was removed.
Corrective action:
No action is necessary.
Severity:
Info
08EF03FF
Power Supply input is restored
Meaning:
The power supply was restored.
Corrective action:
No action is necessary.
Severity:
Info
090B00FF
Fully Redundant
Meaning:
C122-E178-02EN
10