Error
C5A10360
MMB#0 Firmware Update Failed (NOR bank change error)
Meaning:
Switching of NOR bank has failed during the MMB#0 firmware update.
Corrective action:
MMB must be replaced.
Severity:
Error
C5A10361
MMB#1 Firmware Update Failed (NOR bank change error)
Meaning:
Switching of NOR bank has failed during the MMB#1 firmware update.
Corrective action:
MMB must be replaced.
Severity
Error
C5A104FF
Switch Over Failed
Meaning:
MMB Active/Standby switching has failed.
Corrective action:
MMB must be replaced.
Severity:
Error
C5A32XYZ
SB#X was replaced with Reserved SB SB#Y in Partition#Z
Meaning:
A faulty SB#X was switched with Reserved SB#Y in Partition#Z.
Corrective action:
No action is necessary.
Severity:
Info
C5A33X0Y
Reserved SB#X was removed from Partition#Y
Meaning:
Reserved SB#X that was set in Partition#Y was removed.
Corrective action:
No action is necessary.
Severity:
Info
C5A350XY
If SB#X replace with Reserved SB in Partition#Y Memory Mirror is disabled
Meaning:
Mirror Mode setting was Disabled when incorporating a Reserved SB that had been set.
Corrective action:
No action is necessary.
Severity