C9A10F2X
Redundant fan #n failed (PCIBox#n-Slot#n-Port#n,
Cascade #)
Meaning:
The FAN broke down.
X is the broke down FAN number.
Corrective action:
The FAN is mounted in the PSU, and exchange the PSU ahead of time, though the exchange of FAN is
necessary.
Attention) Please do not operate the system with the cover removed. In that case, the operation of FAN is
not guaranteed.
Severity:
Warning
C9A10F30
Temperature has reached the warning level (PCIBox#n-Slot#n-Port#n, Cascade #)
Meaning:
A temperature rise (warning) was detected.
Corrective action:
Confirm the state of FAN. Moreover, lower the ambient temperature.
Attention) Please do not operate the system with the cover removed. In that case, the operation of FAN is
not guaranteed.
Severity:
Warning
C9A10F40
Temperature has reached the critical level (PCIBox#n-Slot#n-Port#n, Cascade #)
Meaning:
A temperature rise (critical) was detected.
Corrective action:
Confirm the ambient temperature. if it is unquestionable, confirm FAN operates normally.
Attention) Please do not operate the system with the cover removed. In that case, the operation of FAN is
not guaranteed.
Severity:
Warning
C9A10F50
Insufficient operating power supplies available (PCIBox#n-Slot#n-Port#n, Cascade #)
Meaning:
A necessary power is not being supplied.
Corrective action:
Confirm the PSU.
Severity:
Warning
C9A10F60
Power supply #n failed (PCIBox#n-Slot#n-Port#n, Cascade #)
Meaning:
There is a possibility that the PSU breaks down.
Corrective action:
Confirm the connection of the power supply cable. If there is no problem in that connection, exchange the
broke down PSU.
Severity:
Warning
C9A10F61
Power supply #n cable removed (PCIBox or IOU #n-Slot#n-Port#n, Cascade #)
Meaning:
Cable of power supply is removed.