Fujitsu PRIMEQUEST 2000 Series Message Reference page 62

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
BC5050D0
PCI: Advisory Non-fatal Bus: $$ Device: 0x$$ Function: 0x$$
Meaning:
An error was detected in the PCI express packet.
Corrective action:
No action is necessary.
Severity:
Info
BC5050E0
PCI: Correctable Internal Error Bus: $$ Device: 0x$$ Function: 0x$$
Meaning:
An internal error was detected in the PCI express Device.
Corrective action:
No action is necessary.
Severity:
Info
BC5050F0
PCI: Header Log Overflow Bus: $$ Device: 0x$$ Function: 0x$$
Meaning:
Many errors were detected in the PCI express packet and the log overflowed.
Corrective action:
No action is necessary.
Severity:
Info
BC507000
Driver Monitor Information: Message ID: $$
Meaning:
An informative event from PCI card driver occurred
Corrective action:
No action is necessary.
Severity:
Info
BC508000
Driver Monitor Warning: Message ID: $$
Meaning:
A warning was detected by PCI driver
Corrective action:
Source of SEL is blank.
After checking Message ID in the SEL message, refer to
action.
Severity:
Warning
BC509000
Driver Monitor Error: Message ID: $$
Meaning:
An error was detected by PCI driver
Corrective action:
Source of SEL is blank.
After checking Message ID in the SEL message, refer to
action.
Severity:
Error