MMB Messages
XX is the HDD number.
Corrective action:
Replace the HDD.
Severity:
Warning
E76F05XX
Physical disk #n rebuilding model=%m (PCIBox#n-Slot#n-Port#n,Cascade #)
Meaning:
The HDD rebuilding is in progress.
XX is the HDD number.
Corrective action:
No action is necessary.
Severity:
Info
E76F0600
Physical disk #n Global hot spare released model=%m (PCIBox or IOU#n-Slot#n-Port#n, Cascade #)
Meaning:
A global hot spare of HDD was deleted.
Corrective action:
No action is necessary.
Severity:
Info
E76F0602
Physical disk #n Global hot spare assigned model=%m (PCIBox or IOU#n-Slot#n-Port#n, Cascade #)
Meaning:
A global hot spare of HDD was generated.
Corrective action:
No action is necessary.
Severity:
Info
E76F0700
Physical disk #n bad block table is full model=%m (PCIBox or IOU#n-Slot#n-Port#n, Cascade #)
Meaning:
Bad block table of HDD exceeded it to capacity.
Corrective action:
Please replace HDD.
Severity:
Warning
E76F0800
Physical disk #n shielded model=%m (PCIBox or IOU#n-Slot#n-Port#n, Cascade #)
Meaning:
The HDD is shielded state.
Corrective action:
Please replace HDD.
Severity:
Warning
E77E01XX
Logical drive #n partially degraded (PCIBox#n-Slot#n-Port#n, Cascade #)
Meaning:
The redundancy is kept though the logical drive did degradation.
XX is the logical drive number.
Corrective action:
When the rebuild is done, it is likely to restore it. Still, when the problem continues, it is necessary to
exchange the HDD.