MMB Messages
Meaning:
The RAID card runs with the battery.
Corrective action:
Confirm the power supply to the RAID card.
Severity:
Warning
297F02FF
BBU on RAID controller: battery low
Meaning:
The battery voltage reduction was detected.
Corrective action:
Confirm whether the cable is correctly connected. Still, when the problem continues, it is necessary to
exchange the FBU.
Severity:
Warning
297F0500
BBU on RAID controller: failed
Meaning:
The battery breakdown was detected.
Corrective action:
The calibration of the FBU is executed. It takes about one day to the completion of this process. Confirm
whether the cable is correctly connected when the problem continues. When the problem is not canceled, it
is necessary to exchange the FBU.
Severity:
Warning
297F0501
BBU on RAID controller: temperature problem detected
Meaning:
Temperature problem of FBU on RAID controller detected
Corrective action:
1. Please confirm the temperature of ambient is in a regulated value.
2. When the problem is not canceled, it is necessary to exchange the FBU.
Severity:
Warning
297F0502
BBU on RAID controller: removed
Meaning:
The voltage has decreased remarkably.
Corrective action:
Please confirm firmware version of the RAID controller and update latest version. Please wait for the charge
completion of the battery. Please exchange FBU when the problem is not canceled after the charge is
completed.
Severity:
Warning
297F0503
BBU on RAID controller: BBU/charger problem detected; SOH bad
Meaning:
The charge with the battery is insufficient.
Corrective action:
Please exchange FBU.
Severity:
Warning
297F0504
BBU on RAID controller: Error with the remote BBU connector cable detected
Meaning:
Problem of the cable of FBU was detected.