MMB Messages
Severity:
Warning
■Memory Module Related (BMC)
B0E10F00
Memory module (s) changed
Meaning:
The mounting positions were swapped.
Corrective action:
No action is necessary.
Severity:
Info
■SDR OEM Multiple Sensor related (BMC)
B0EE8300
ASR&R counter exceeded restart tries
Meaning:
The ASR counter has exceeded the number of retries.
Corrective action:
No action is necessary.
Severity:
Info
■PCI related (BMC)
BC503080
Legacy PCI Master Data PERR Bus: $$ Device: 0x$$ Function: 0x$$
Meaning:
Error has been detected in the PCI or PCI express data.
Corrective action:
Referring the Source and Unit of the MMB system event log, replace the unit according Replacement
Component Type B in the
Severity:
Error
BC5030B0
Legacy PCI Target Abort Bus: $$ Device: 0x$$ Function: 0x$$
Meaning:
Error has been detected in the PCI or PCI express data.
Corrective action:
Referring the Source and Unit of the MMB system event log, replace the unit according Replacement
Component Type B in the
Severity:
Error
BC5030C0
Legacy PCI Received Target Abort Bus: $$ Device: 0x$$ Function: 0x$$
Meaning:
Error has been detected in the PCI or PCI express data.
Corrective action:
Referring the Source and Unit of the MMB system event log, replace the unit according Replacement
Component Type A in the