Fujitsu PRIMEQUEST 2000 Series Message Reference page 82

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
E76F08FF
Physical disk shielded model=%m
Meaning:
The HDD is shielded state.
Corrective action:
Replace the HDD.
Severity:
Warning
E7EF06FF
Physical disk Global Hot Spare deleted model=$$
Meaning:
The HDD global hot spare was deleted.
Corrective action:
No action is necessary.
Severity:
Info
E77E01FF
Logical drive partially degraded
Meaning:
The redundancy is kept though the logical drive did degradation.
Corrective action:
Replace the HDD.
Severity:
Warning
E77E02FF
Logical drive degraded
Meaning:
The logical drive did degradation and the redundancy was lost.
Corrective action:
Replace the HDD.
Severity:
Warning
E77E04FF
Logical drive bad block table is full
Meaning:
The bad block table of logical drive is full.
Corrective action:
Check added error messages for the logical drive.
Severity:
Warning
E77E03FF
Logical drive failed
Meaning:
The logical drive broke down.
Corrective action:
It is likely to be able to recover without losing data. Please gather the survey material because a detailed
investigation is necessary for that and contact the repair chat channel.
Severity:
Warning
297F01FF
BBU on RAID controller: on battery
C122-E178-02EN