MMB Messages
If there is no problem with the settings of the backup software, replace the drive.
Severity:
Warning
14024
Device or Software error (Overrun)
Meaning:
A device or application error occurred. An overrun occurred on a variable-length device.
Corrective action:
If you were working on a DAT by using a command such as dd, confirm that the specified parameters are
correct. If you are sure that there is no mistake in the work, a hardware failure occurred. Replace the drive.
Severity:
Warning
14025
Device or Software error (Incorrect block size)
Meaning:
A device or application error occurred. The block size or the size specified for read is invalid for a fixed-
length device.
Corrective action:
Check the block size for read. If there is no problem with the block size, replace the drive.
Severity:
Warning
14027
Device or Software error (Partitioning of tape failed)
Meaning:
A device or application error occurred. Partitioning of the tape device failed.
Corrective action:
Check whether the drive supports partitioning. If the drive does not support it, modify the software settings. If
the drive supports it, replace the drive.
Severity:
Warning
14054
Device error (ioctl error)
Meaning:
Warning. ioctl error. Device or Driver problem. (Non-removable drive, some error occurred during ioctl.)
Corrective action:
Identify the type of the target unit from its host, id, and lun. Then, check the sense key (extended sense) in
the original message to determine the corrective action.
1 (Recovered Error): If it is a removable device, perform cleaning.
2 (Not Ready): If it is non-removable, replace the device.
3 (Medium Error): If it is a disk, replace the device. If it has removable media, perform cleaning and replace
the media.
4 (Hard Error): Replace the device.
5 (Illegal Request): Examine the software.
6 (Unit Attention): This is notification information from various devices. (e.g., reset status, RAID degradation
if applicable)
7 (Data Protect): Check the Write Protect status.
8 (Blank Check): Check tape and other operations.
9 (Aborted Command): Investigate problems in the SCSI bus and FC transmission paths.
If the problem persists, contact your sales representative or a field engineer.
Severity:
Warning
14060
Device error (Medium error or Volume overflow)
Meaning:
A media error or volume overflow occurred.