MMB Messages
Log files have not been saved. Are you sure you want to continue?
Meaning:
The confirmation window appears when the [Next] button in the log saving window is clicked without saving
the log data, asking whether to proceed to the next window without saving the log files.
Corrective action:
If the log files need not be saved, click the [OK] button to proceed to the next window. Otherwise, click the
[Cancel] button to display this window and save the log files.
Severity:
Info
W_00211
The unit is not present. Maintenance will be canceled.
Are you sure?
Meaning:
After replacement or expansion is instructed, if the [Next] button in this window is clicked without the unit
mounted, the subsequent maintenance procedures are skipped to display the completion window.
Corrective action:
After the [Previous] button is clicked and when the replacement or expansion instruction window appears,
mount the target unit. After completing the mounting, open this window again and continue the operation.
Severity:
Warning
I_00212
System Power Control cannot be executed because the system is under maintenance.
Meaning:
Execution of power control is not permitted during maintenance.
Corrective action:
Wait until the maintenance work is completed and maintenance mode is released.
Severity:
Info
W_00212
The powering on has been skipped because there is no partition whose configuration satisfies power
on requirements.
After Maintenance completion, Check the partition configuration in the Partition Configuration
Window.
Meaning:
During Cold System Maintenance, an attempt was made to turn on the power to all partitions, but the power
could not be turned on, because there were applicable partitions.
Corrective action:
As skipping the power on operation does not affect the maintenance work. Review the partition configuration.
Severity:
Warning
I_00213
%aa cannot be executed because the system is under maintenance.
Meaning:
%aa cannot be performed during maintenance.
Corrective action:
Wait until the maintenance work is completed and maintenance mode is released.
Severity:
Info
I_00214
Unable to Power On the Partition#%aa because this Partition is under maintenance.
Meaning:
Power to partition#%aa cannot be turned on because maintenance is in progress.
Corrective action:
Wait until the maintenance work is completed and maintenance mode is released.
Severity:
C122-E178-02EN
153