MMB Messages
Severity:
Warning
E77E02XX
Logical drive #n degraded (PCIBox#n-Slot#n-Port#n,Cascade #)
Meaning:
The logical drive did degradation and the redundancy was lost.
XX is the logical drive number.
Corrective action:
When the rebuild is done, it is likely to restore it. Still, when the problem continues, it is necessary to
exchange the HDD.
Severity:
Warning
E77E03XX
Logical drive #n failed (PCIBox#n-Slot#n-Port#n, Cascade
#)
Meaning:
The logical drive#n broke down.
Corrective action:
It is likely to be able to recover without losing data. Please gather the survey material because a detailed
investigation is necessary for that and contact the repair chat channel.
Severity:
Warning
E77E0400
Logical drive #n bad block table is full (PCIBox or IOU#n-Slot#n)
Meaning:
Bad block table of logical drive is full.
Corrective action:
Please confirm added error message of the disk drive.
Severity:
Warning
C9A10F0X
Fan#n will fail in near future (PCIBox#n-Slot#n-Port#n,Cascade #)
Meaning:
The FAN will break down in the near future.
X is the FAN number.
Corrective action:
The FAN is mounted in the PSU, and exchange PSU ahead of time, though the exchange of FAN is
necessary.
Attention) Please do not operate the system with the cover removed. In that case, the operation of FAN is
not guaranteed.
Severity:
Warning
C9A10F1X
Fan#n failed (PCIBox#n-Slot#n-Port#n, Cascade #)
Meaning:
The FAN broke down.
X is the broke down FAN number.
Corrective action:
The FAN is mounted in the PSU, and exchange the PSU ahead of time, though the exchange of FAN is
necessary.
Attention) Please do not operate the system with the cover removed. In that case, the operation of FAN is
not guaranteed.