Fujitsu PRIMEQUEST 2000 Series Message Reference page 81

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
Warning
C8A70E09
BBU on RAID controller: communication error
Meaning:
The communication error with FBU occurred.
Corrective action:
1. Please confirm that data cable and power cable of FBU are correctly connected with RAID controller.
2. Please confirm that latest firmware version of the RAID are installed.
3. When the problem is not canceled, it is necessary to exchange the FBU.
4. When the problem is not canceled, please gather the survey material because a detailed investigation is
necessary for that and contact the repair chat channel.
Severity:
Warning
E76F02FF
Physical disk SMART error (predictive failure) model=$$
Meaning:
The HDD error was detected by self-diagnosis.
Corrective action:
Replace the HDD.
Severity:
Warning
E76F03FF
Physical disk failed model=$$
Meaning:
The HDD error was detected.
Corrective action:
Replace the HDD.
Severity:
Warning
E76F05FF
Physical disk rebuilding model=$$
Meaning:
The HDD rebuilding is in progress.
Corrective action:
No action is necessary.
Severity:
Info
E76F06FF
Physical disk Global Hot Spare created model=$$
Meaning:
The HDD global hot spare was created.
Corrective action:
No action is necessary.
Severity:
Info
E76F07FF
Physical disk bad block table is full model=%m
Meaning:
The bad block table of HDD is full.
Corrective action:
Replace the HDD.
Severity:
Warning
C122-E178-02EN
65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents