Fujitsu PRIMEQUEST 2000 Series Message Reference page 128

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
If the error recurs, collect investigation materials (e.g., fjsnap, PrimeCollect), and contact your sales
representative or a field engineer.
Severity:
Warning
28724
Adapter error (Flashback error)
Meaning:
A flashback error occurred.
Corrective action:
1. Back up the data from the affected adapter.
2. Replace the adapter.
3. Restore the data.
Severity:
Warning
28725
Adapter error (Non-correctable PCI errors detected)
Meaning:
An uncorrectable PCI error was detected.
Corrective action:
If the error recurs, collect investigation materials (e.g., fjsnap, PrimeCollect), and contact your sales
representative or a field engineer.
Severity:
Warning
28726
Adapter error (Temperature above warning threshold)
Meaning:
The temperature has exceeded the warning threshold.
Corrective action:
Check the ambient temperature, and reduce the write load.
Severity:
Warning
28727
Adapter error (Memory is close to wearing out)
Meaning:
The system is running short of memory.
Corrective action:
Check the format size. Release reserved space by formatting with a smaller size.
Severity:
Warning
28728
Adapter error (Non-optimal PCI slot bandwidth)
Meaning:
The PCI slot does not have the optimal bandwidth.
Corrective action:
Reinstall the adapter at an appropriate PCI slot.
Severity:
Warning
28729
Adapter error (Power loss protection disabled)
Meaning:
Power loss protection is disabled.
Corrective action:
C122-E178-02EN