MMB Messages
Meaning:
The entered file is outside the restoration target.
The file specified as the restoration target is not the MMB (BIOS) configuration information backup file.
Corrective action:
Specify the correct file.
Severity:
Error
W_00068
There are no available unit on which maintenance can be performed.
Please check that you selected the right type of unit, then check that the power status of partitions is
Standby in the Partition Power Control Window, and that there is available free units in the Partition
Configuration Window.
Then please try again.
Meaning:
There is not unit for maintenance. Check if the selected unit is correct, and power status is Standby in the
partition of the [Partition Power Control] window, or if the unit selected in the partition Configuration window
is Free. After checking, perform the maintenance operation again.
Corrective action:
Confirm the maintenance unit and execute the operation again.
Severity:
Warning
E_00069
Can't control system power under maintenance. Release maintenance mode.
Meaning:
The system power cannot be operated during maintenance.
Corrective action:
Execute the operation after completion of the maintenance.
Severity:
Error
E_00075
Partition#%aa cannot execute sadump
Meaning:
sadump cannot be executed in Partition#%.
sadump startup has failed.
Corrective action:
Check if sadump is installed in the partition.
Severity:
Error
E_00077
Partition#%aa cannot execute Power On.
Meaning:
Partition#%aa cannot be powered on.
Corrective action:
Check if the partition configuration is correct.
Severity:
Error
E_00078
Partition#%aa cannot execute Power Off.
Meaning:
Partition#%aa cannot be powered off.
Corrective action:
Check the partition status.
Severity:
Error