NEC Xen IPK Features & Specifications Manual page 72

Phone system
Hide thumbs Also See for Xen IPK:
Table of Contents

Advertisement

July 2003
SERVICE
CONDITIONS
62 – A16
N
5.
Press
to enter the information. The next Account Number
is displayed. Repeat steps 4~5 until all desired Account Codes
are entered.
P
6.
Press
to stop entering Forced Account Codes/Authorisation
Codes.
Verified or Unverified for the Forced Account Code/Authorisation Code
features.
Memory Block 1-8-08 (Class of Service (Station) Feature Selection 2),
Page 6, LK 3 is used to activate assign Verified or Unverified for the
Forced Account Code/Authorisation Code features.
When a call is made without using an authorisation code, memory
blocks 4-64 and 4-65 are used to assign the code restriction class.
When a call is made using an authorisation code, the code restriction
class is temporarily changed and Memory Blocks 4-07 and 4-08 are
used to assign the code restriction class.
After placing a call using an authorisation code, if the Recall or Drop
keys are used, the temporary code restriction class remains with the
setting assigned in Memory Blocks 4-07 and 4-08 allowing the user to
dial another non-restricted number.
After placing a call using an authorisation code, when the station goes
idle (On-hook), the code restriction class is reset to its previous setting
assigned in Memory Blocks 4-64 and 4-65.
A total of 500 Forced Account Codes/Authorisation Codes can be
entered system-wide.
Forced Account Codes/Authorisation Codes and Account Code entries
Codes are printed on the SMDR report, if both are used.
A
is placed in front of the Forced Account Codes/Authorisation
Codes on the SMDR reports to distinguish them from other Account
Code entries.
When the Interdigit time (default is 10 seconds) expires during the user
input of a Forced Account Codes/Authorisation Code, Busy Tone is
generated.
PBR Time values apply when a Single line Telephone is used to enter
a Forced Account Code/Authorisation Code.
Forced Account Codes/Authorisation Codes can be uploaded,
downloaded, or modified using PC-based System Programming.
Restrictions
A Forced Account Code/Authorisation Code has a maximum of
13 digits.
The Authorisation Code feature is only provided from intercom dial
tone. Direct access to trunks is bypassed by pressing CO Line Keys.
NEC Business Solutions Ltd
Authorisation Code

Advertisement

Table of Contents
loading

Table of Contents