General Purpose Relays

FEATURE
DESCRIPTION
SYSTEM
AVAILABILITY
OPERATING
PROCEDURES
Features and Specifications Manual
Two relays located on the ECR-U( ) ETU are designated for use as an
application dictates. These relays are either off or on, and do not change
state until a station user manually makes the change.
Terminal Type
All Multiline Terminals.
Attendant Add-on Console.
Required Components
ECR-U( ) ETU
To control the General Purpose Relay from the Attendant Add-on
Console:
1.
Press the key assigned GPR0 or GPR1.
2.
The GPR LED is on (red) to indicate the relay is closed (on), or Off to
indicate the relay is open (off).
To control the General Purpose Relay from a Multiline Terminal:
To turn the GPR relay on:
T
1.
Press
+
.
0
2.
Dial the relay number
3.
Dial the desired number +
To turn the GPR relay off:
T
1.
Press
+
0
2.
Dial the relay number
T
J
3.
Dial the
+
A
0
or
(for GPR0 or GPR1).
T
.
.
A
or
(for GPR0 or GPR1).