General
LCR access is assigned per station in LCR Class Selection.
LCR is programmed via a Personal Computer and diskette through the
MIFM-U( ) ETU. This connection is the same as the PC programming
connection.
Trunk Group Access Code (0 set as default) activates LCR at stations
assigned for LCR.
LCR is based on the first eight digits dialled.
When using Code Restriction with LCR, Code Restriction is applied to
the digits dialled by the system.
Extra Code Tables can be programmed to provide Trunk Access
Codes, OCC Access Codes, and pauses for the distant-end system.
The maximum number of extra code digits is 32, including pauses
(each pause counts as one digit).
LCR provides up to eight different routes for each call.
If the station user seizes the most expensive trunk, alarm tone is not
provided.
When the interdigit time exceeds 10 seconds, the outgoing call, via
LCR, is disconnected.
When the station user places an outside call using LCR, Trunk
Queuing cannot be set.