D-Link DWS-3160-24TC Reference Manual page 177

Dws-3160 series web ui reference guide gigabit ethernet unified switch
Hide thumbs Also See for DWS-3160-24TC:
Table of Contents

Advertisement

DWS-3160 Series Gigabit Ethernet Unified Switch Web UI Reference Guide
The fields that can be configured are described below:
Parameter
Access ID (1-100)
Action
Flow Label
Time Range Name
Ports
Click the Apply button to accept the changes made.
Click the <<Back button to discard the changes made and return to the previous window.
After clicking the Show Details button in the CPU Access Rule List, the following page will appear:
Click the Show All Rules button to navigate back to the CPU Access Rule List.
Figure 10-37 Add CPU Access Rule (IPv6 ACL)
Description
Enter a unique identifier number for this access. This value can be set from 1 to 100.
Select Permit to specify that the packets that match the access profile are forwarded by
the Switch, according to any additional rule added (see below).
Select Deny to specify that the packets that match the access profile are not forwarded
by the Switch and will be filtered.
Configuring this field, in hex form, will instruct the Switch to examine the flow label field
of the IPv6 header. This flow label field is used by a source to label sequences of
packets such as non-default quality of service or real time service packets.
Tick the check box and enter the name of the Time Range settings that has been
previously configured in the Time Range Settings window. This will set specific times
when this access rule will be implemented on the Switch.
Ticking the All Ports check box will denote all ports on the Switch.
Figure 10-38 CPU Access Rule Detail Information (IPv6 ACL)
172

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dws-3160 seriesDws-3160-24pc