Message
System over temperature for CPU "X"
(level-warning; CPU "X" reporting over temperature
condition)
System under recommended CPU "X" temperature
(level-warning; system reporting under temperature
condition for CPU "X")

Fan error messages

Message
Fan "X" failure (level-critical; fan "X" had a failure)
Fan "X" fault (level-critical; fan "X" beyond
recommended RPM range)

Power error messages

Power supply "X" current fault (level-critical; excessive
current demand on power supply "X")
Power supply "X" DC good fault (level-critical; power
good signal not detected for power supply "X")
Power supply "X" fan fault (level-critical; fan fault in
power supply "X")
Power supply "X" fault (level-critical; overcurrent
condition exists)
Power supply "X" 12V fault
overcurrent condition detected)
Power supply "X" 3.3V fault
3.3V power supply "X" had an error)
Power supply "X" 5V fault (level-critical; 5V power supply
"X" had an error)
System over recommended "X" current
critical; system running too much current on that voltage)
System running non-redundant power
critical; system does not have redundant power)
Message
(level-critical;
(level-critical;
(level-non-
(level-non-
1.
Ensure system is being properly cooled; see
"Temperature checkout" on page 31.
2.
Replace CPU "X".
3.
Replace Processor/PCI Board.
1.
Ambient temperature must be within normal operating
specifications; (see "Features and specifications" on page
3).
2.
Replace CPU "X".
3.
Replace Processor/PCI Board.
1.
Check connections to fan "X"
2.
Replace fan "X"
1.
Check connections to fan "X"
2.
Replace fan "X"
1.
See "Power checkout" on page 31.
1.
Replace power supply "X"
1.
Replace power supply "X"
1.
See "Power checkout" on page 31.
1.
See "Power checkout" on page 31.
1.
See "Power checkout" on page 31.
1.
See "Power checkout" on page 31.
1.
See "Power checkout" on page 31.
1.
Add another power supply
2.
Remove options from system
3.
System can continue to operate without redundancy
protection if 1 and 2 above are not followed.
Action
Action
Action