Terminal Interface Messages

This section contains descriptions of error messages that can occur while using the
Terminal Interface. The error messages are listed in numerical order, and each
description includes the cause of the error and the action you should take to remedy
the situation.
The emulator can return messages to the display only when it is prompted to do so.
Situations may occur where an error is generated as the result of some command,
but the error message is not displayed until the next command (or a carriage return)
is entered.
A maximum number of 8 error messages can be displayed at one time. If more
than 8 errors are generated, only the last 8 are displayed.

Emulator Messages

4
Coverage measurement not supported
Cause: You attempted to use the cov Terminal Interface command for an emulator
that does not provide coverage memory.
40
Restricted to real time runs
Cause: While the emulator is restricted to real-time execution, you have attempted
to use a command that requires a temporary break in execution to the monitor. The
emulator does not permit the command and issues this error message.
Action: You must break the emulator's execution into the monitor before you can
enter the command.
61
Emulator is in the reset state
Cause: You have entered a command that requires the emulator to be running in
the monitor (for example, displaying registers).
Action: Enter the break command to cause the emulator to run in the monitor, and
enter the command that caused the error again.