Parameter
Default
Value Range
Description/Function
Reference
Parameter
Default
Value Range
Description/Function
Reference
Parameter
Default
Value Range
Description/Function
Reference
Programming Guide
Signaling Bit Monitor (Port No.)
Disable
1.
Disable
2.
Port No. 1-24
Specifies the port to monitor the signaling bit using the LED on the
T1 card.
Note
• This setting is valid when the LPR software version of the T1
card is "Y311D" or later.
• 4.7 Digital Trunk Details (I/M)
Signaling Bit Monitor (Mode)
Mode 3
1.
Mode 1
2.
Mode 2
3.
Mode 3
Specifies the signaling bit to be monitored using the LED on the T1
card.
1.
Mode 1: LED (SYNC ERROR/RAI/AIS/SYNC)=
(TR-A/TR-B/TR-C/TR-D bit)
2.
Mode 2: LED (SYNC ERROR/RAI/AIS/SYNC)=
(RX-A/RX-B/RX-C/RX-D bit)
3.
Mode 3: LED (SYNC ERROR/RAI/AIS/SYNC)=
(TR-A/TR-B/RX-A/RX-B bit)
Note
• This setting is valid when the LPR software version of the T1
card is "Y311D" or later.
• 4.7 Digital Trunk Details (I/M)
Software Information
(Display only)
Displays the ROM version of the T1 card software and ROM
checksum.
• 4.6 Digital Trunk Error Report (I/M)
• 4.7 Digital Trunk Details (I/M)