Panasonic LX-TD500 Programming Manual page 207

Digital super hybrid system
Table of Contents

Advertisement

Parameter
Default
Value Range
Description/Function
Reference
Parameter
Default
Value Range
Description/Function
Reference
Programming Guide
Wink Signal Time-out
1024 ms
1.
64 ms
2.
128 ms
3.
256 ms
4.
512 ms
5.
1024 ms
6.
2048 ms
7.
4096 ms
8.
8128 ms
Specifies the length of time in milliseconds that the system is to
wait for the Wink Signal after seizing the trunk.
(Assignable only when "Start Signal Type" is set to "Wink"; the
case of the DID card is excluded.)
• 3.1 TIE Line Features (F/G)
– TIE Line Service
Start Signal Type
Wink
1.
Immediate
2.
Wink
Specifies the start signal type for a DID and TIE (E&M) trunk.
1.
Immediate:
The system sends the dialing digits to CO after waiting for the
time length determined by "First Dial Timer" in "Card
Properties" screen of the corresponding trunk card.
For information on "Card Properties" screen, please refer to
"Card Type" in Section "1.2 Slot Assignment."
2.
Wink:
The system sends the dialing digits to CO after receiving the
wink signal.
• 3.1 TIE Line Features (F/G)
– TIE Line Service
• 1.5 Attended Features (F/G)
– Direct Inward Dialing (DID)
Line
207

Advertisement

Table of Contents
loading

Table of Contents