Panasonic LX-TD500 Programming Manual page 14

Digital super hybrid system
Table of Contents

Advertisement

Configuration
Parameter
Default
Value Range
Description/Function
Reference
Parameter
Default
Value Range
Description/Function
Reference
1.2.3 Card Properties (DHLC/ESLC/DLC)
Used to set the parameters for the following extension cards: DHLC, ESLC, DLC
14
% Break Detection
16-96 ms
1.
16-96 ms
2.
16-136 ms
Specifies the Pulse Break Detection length.
Dialed digits from a dial pulse type SLT are transmitted to the
system by making and breaking a loop current, thereby interrupting
loop current. Duration time required to detect the number of breaks
may vary depending on the type of SLT connected.
None
Flash Detection
Yes
1.
Yes
2.
No
Activates or deactivates the detection of Flash signal transmitted
from an SLT.
This determines the treatment of the call after an SLT user flashes
the switchhook.
If set to "Yes," the system will place the call on consultation hold.
Therefore, flash detection is enabled. If set to "No," the system will
disconnect the call. In other words, flash detection is disabled.
None