Panasonic LX-TD500 Programming Manual page 158

Digital super hybrid system
Table of Contents

Advertisement

Group
Parameter
Default
Value Range
Description/Function
Reference
Parameter
Default
Value Range
Description/Function
Reference
158
Flash Time
600 ms
1.
None
2.
80 ms
3.
300 ms
4.
600 ms
5.
900 ms
6.
1200 ms
Specifies the length of flash time.
Notes
• When you need finer resolution, assign this to 80 ms and use
"Flash Time" parameter in Section "1.2.5 Card Properties
(ELCOT)."
• You must use "Flash Time" parameter in Section "1.2.5 Card
Properties (ELCOT)" when your Central Office requires a
Flash Time not listed here.
None
Disconnecting Time
1.5 s
1.
0.5 s
2.
1.5 s
3.
2.0 s
4.
4.0 s
5.
12.0 s
Specifies the maximum time in seconds the system is to wait after
releasing the trunk line before getting it again.
Note
• This allows the Central Office an opportunity to release its
resources before another trunk call is placed from the PBX.
None