Neutral Adjustment (continued)
Hydrostatic Drive System: Service and Repairs
3. Remove the 4 (13/16 inch) lug nuts securing rear wheel to the hub. Remove
the wheel from the machine.
4. Disconnect the seat switch.
g302064
5. Install an appropriate jumper to disable the seat switch.
6. Start the machine.
7. Move the motion control lever until neutral is found. Once neutral is found,
install an M8X1.00 nut onto the neutral lock stud for the transmission.
g302065
8. Tighten the nut to lock the neutral position.
9. Loosen the 7/16 inch nut securing the 2 motion control levers.
Figure 232
Figure 233
Page 6–10
TIMECUTTER® Service Manual