Disconnecting Power On An Dc-Powered M10I Router - Juniper M10i Hardware Manual

Multiservice edge router
Hide thumbs Also See for M10i:
Table of Contents

Advertisement

M10i Multiservice Edge Router Hardware Guide
Related
Documentation

Disconnecting Power on an DC-Powered M10i Router

70
All manuals and user guides at all-guides.com
Press the power switch for the power supplies in slots
6.
position. The power switch is located on the power supply faceplate.
The Routing Engine boots as the power supply completes its startup sequence. If the
Routing Engine finishes booting and you need to power off the router again, see
"Powering Off an M10i Router" on page 71. After powering on a power supply, wait at
least 60 seconds before turning it off.
NOTE: After a power supply is powered on, it can take up to 60 seconds
for status indicators—such as LEDs on the power supply and command
display output—to indicate that the power supply is functioning normally.
Ignore error indicators that appear during the first 60 seconds.
Press the power switch for any additional power supplies to the
7.
Verify that the green
OUTPUT OK
8.
NOTE: If the LED does not light after 60 seconds, verify that the power
supply is properly inserted into the chassis and repeat the cable installation
procedures described in "Connecting Power on an DC-Powered M10i
Router" on page 67.
On the external management device connected to the Routing Engine, monitor the
9.
startup process to verify that the system has booted properly.
Connecting to a Management Console or Auxiliary Device on page 62
Connecting to a Network for Out-of-Band Management on page 62
Preventing Electrostatic Discharge Damage to an M10i Router on page 150
General Electrical Safety Guidelines and Electrical Codes for M10i Routers on page 167
M10i DC Power Supply Description on page 26
M10i Router DC Power Supply Specifications on page 191
To disconnect DC power from the router:
Power off the router (see "Powering Off an M10i Router" on page 71).
1.
For each power supply, press the power switch on the DC power supply faceplate to
2.
the
OFF
(
O
) position.
Shut off the power flowing from both external power sources, so that the voltage
3.
across the leads of the DC power cables is 0 V. Ensure that there is no chance that
the cable leads might become active during the procedure.
P/S 0
LED on each power supply faceplate lights steadily.
Copyright © 2010, Juniper Networks, Inc.
and
to the
(
)
P/S 1
ON
|
(
) position.
ON
|

Advertisement

Table of Contents
loading