Figure 13: Airflow Through the Chassis

The fan tray is hot-removable and hot-insertable, as described in "M10i Field-Replaceable
Units (FRUs)" on page 99. For instructions on replacing it, see "Replacing an M10i Fan
Tray" on page 101.
CAUTION: Do not remove both fan trays for more than one minute while the
router is operating. The fans are the sole source of cooling, and the router
can overheat when they are absent.
Installing an M10i Fan Tray on page 102
M10i Router Description on page 3
Maintaining the M10i Cooling System on page 80
Troubleshooting the M10i Fan Tray on page 91
The cable management system consists of racks that attach vertically to each side of
the chassis at the front, as shown in Figure 14 on page 29. Pass PIC cables through the
slots in the racks to keep the cables organized and securely in place, and to avoid bending
optical cables beyond the proper bend radius. The cable management system evenly
distributes the weight of a cable, so that it is not subjected to undue stress at the
connector.