Installing an M10i HCM

Copyright © 2010, Juniper Networks, Inc.
All manuals and user guides at all-guides.com
CAUTION: Slide the HCM straight out of the chassis. Damage can result
if it gets lodged because of uneven movement.
Place one hand under the HCM to support it, slide it completely out of the chassis,
10.
and place it on the antistatic mat or in the electrostatic bag.

Figure 38: Removing a Routing Engine

Figure 39: Removing an HCM

To install an HCM (see Figure 40 on page 110 and Figure 41 on page 110):
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
1.
the strap to one of the ESD points on the chassis.
Place one hand under the HCM to support it and grasp the handle on the faceplate
2.
with the other hand.
Align the rear of the HCM with the guide rails inside the chassis and slide it in
3.
completely.
CAUTION: Align the HCM carefully with the guide rails and push it in evenly.
Damage can result if it gets lodged in the rails because of uneven
movement.
Chapter 15: Replacing M10i Hardware Components