Specifications
No.
Designation
S-LINK V terminal block
1
connector
Operation mode selector
2
switch (power switch)
3
Error indicator × 6 (Red)
4
ERROR CLEAR key
Address display
5
(Red)
6
ENTER key
7
SELECT keys
8
Mode selector switch
Hexadecimal number
9
display mode indicator
(Orange)
Transmission mode indicator
10
(Green)
Address display
11
(Red)
12
ENTER key
13
SELECT keys
Input address
14
indicator (Green)
Output address
15
indicator (Orange)
Data monitor indicator
16
(Orange)
Data input validity
17
indicator (Green)
Data input VALID /
18
INVALID selector key
19
Data input switches
150
1: F.G.
2: 24V
3: 0V
4: +24V
Receives +24V, 0V, and F.G. from the external power supply unit, and supplies +24V, 0V,
D, and G to the I/O units. In addition, the error output signal is output to the external device.
5: 0V
6: D
7: 0V
8: ERR
Selects the master mode, power-off mode, or slave mode.
Lights up when an error occurs in the master mode, blinks when the error is canceled (turns off when the
ERROR CLEAR key is pressed).
After occurrence of an error, if the error indicator (red) starts blinking (the cause of the error is eliminat-
ed), press this key. The error indicator will light off.
The displayed item depends on the mode ('RUN,' 'CHECK', or 'CONFIG' mode).
Use the mode selector switch to switch the mode.
<RUN mode>
• Each transmission mode (3 modes in total) will be indicated by the following character, and the LED of
each character will sequentially light up just like rotating clockwise.
A Mode
• If an error occurs, the error message will appear.
<CHECK mode>
• The number of connected nodes will be displayed first. After that, each time you press the SELECT
key, the recognized addresses will be displayed one after another.
Number of connected nodes:
Using the decimal or hexadecimal number, the number of I/O units will be displayed.
Address:
Using the decimal or hexadecimal number, the addresses of the I/O units will be displayed sequentially.
Note: In the hexadecimal number display mode, the hexadecimal number indicator (orange) will light up.
<CONFIG mode>
• Settings will be displayed sequentially. To switch the displayed setting, use the SELECT key.
• When the RUN mode is switched to the CONFIG mode, different item will be displayed compared with
the displayed item just after power-on.
Press the ENTER key to determine the set condition value.
In the system setting mode, press and hold the ENTER key for 3 seconds or more.
The system will be set.
Use these keys to switch the displayed item or set item. Also use these keys to change the set condition
value.
Switches the mode ('RUN,' 'CHECK', or 'CONFIG' mode).
Indicates the current display mode of the address display.
• ON: The hexadecimal number display mode is selected.
• OFF: The decimal number display mode is selected.
This indicator will blink during transmission (when the transmission signal is being output).
The indicator blinking cycle depends on the transmission speed.
Displays the input address or the output address.
Starts setting an address or determines an address.
You can also use this key to change the displayed address.
Use these keys to set address values or to change the displayed address.
Lights up when the address display on the ADDRESS SET side displays the input address.
Lights up when the address display on the ADDRESS SET side displays the output address.
Lights up when signals of 16 specified output addresses (the first address is specified) are turned ON.
Lights up when data input is valid (if data input using the data input switch is possible.)
Switches the data input mode to 'VALID' or 'INVALID.'
Press and hold this switch for 1 second or more to switch the data input mode.
Inputs data by inputting 16 addresses of signals to the S-LINK V system.
Function