Panasonic S-LINK V User Manual page 63

Flexible wire-saving system
Hide thumbs Also See for S-LINK V:
Table of Contents

Advertisement

1
Starting system at the
completion of installation
2nd and subsequent times
Change in system
control conditions
Unnecessary
Turn on the power (Note).
Set the mode selection switch of the
controller to CHECK.
Check the number of connection nodes
of each unit and the set address.
Compare the
checked (indicated) number
of connected nodes with the
number of installed units.
Same
Set the mode selection switch of the
controller to RUN.
Completion of check
Note: If both the main and local power supply units are connected, be sure to turn on the local power supply unit first.
1st time
Necessary
Set the mode selection switch of the
controller to CONFIG.
Turn on the power (Note).
Set the items to be indicated on the
controller.
Switch the indication, and select the system
setting mode. Press and hold the ENTER
key until the indication blinks (3 seconds).
Setting check in CHECK mode (page 70)
Different
Check the indicator of each I/O unit.
Turn off the power.
Set each unit address again.
Check the wiring condition.
Initial setting in CONFIG mode (page 66)
Execution of system setting
Flowchart
63

Advertisement

Table of Contents
loading

Table of Contents