Panasonic S-LINK V User Manual page 116

Flexible wire-saving system
Hide thumbs Also See for S-LINK V:
Table of Contents

Advertisement

Specifications
● Specifications
Type
Model No.
Applicable connector
Supply voltage
Current consumption
Allowable passing current
(Note 2)
Address setting
Input
Number of input points
Transmission indicator
Input indicator
Ambient temperature
(Note 3, 4)
Ambient humidity
Noise immunity
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Mounting
Tightening torque
Material
Cable
Weight
Accessory
Notes: 1) Purchase separately a compliant product with MIL-C-83503.
2) Each value includes the current consumption of this unit and connected machine.
3) If this product is stored in the control panel together with the other units, the temperature may rise above the specified operation tem-
perature due to the heat generated by the other units.
In this case, install a cooling fan, etc. so that the ambient temperature can be in the specified range.
4) In some cases, you cannot install the same SL-VT16C1 units close to each other, or SL-VT16C1 units and other I/O units close to
each other. The distance between these units depends on the ambient temperature.
While referring to the following figure, secure enough distance between the units.
116
24V DC±10% (Supplied from S-LINK V controller or separate power supply)
Photo-coupler input:
• Current input: 5mA or less
• Operation voltage:
ON voltage: 17V or more (between input and +24V)
OFF voltage: 4V or less (between input and +24V)
• Input impedance: Approx. 6.3kΩ
Green LED (blinks when the synchronization signal is sent from the S-LINK V controller)
Green LED (lights up when the input signal of the corresponding channel is turned ON)
-10 to +55ºC (No dew condensation or icing allowed), Storage: -20 to +70ºC
Power line: 500Vp, 10ms cycle, 1μs pulse width
Common: 1,000Vp, 10ms cycle, 1μs pulse width (with noise simulator)
1,000V AC for one min. between all terminals connected together and enclosure
20MΩ, or more, with 500V DC megger between all terminals connected together and enclosure
10 to 150Hz frequency, 0.75mm amplitude or maximum acceleration 49m/s² in X, Y and Z directions for two
hours each
2
490m/s
acceleration (approx. 50G) in X, Y and Z directions for three times each
Mounted on DIN rail or by tightening screws
16
12
8
4
0
10 20 30 40 5055
-10 0
Ambient temperature (°C)
MIL connector input unit
SL-VT16C1
20-pin MIL connector (header) (Note 1)
80mA or less (when all points are ON)
Total: 1.2A or less
Using switches, in the range of 0 to 511
16 points
35 to 85% RH, Storage: 35 to 85% RH
Mounting screw: 0.8N·m or less
Enclosure: ABS, Mounting base: POM
2
0.5mm
4-core flat cable, 0.6m long
Approx. 80g
Connector I/O unit mounting base: 1 pc.
To horizontally install the units
Units
L≥25
L=20
L=15
L=10
To vertically install the units
L=5
L=0
L
Units
L

Advertisement

Table of Contents
loading

Table of Contents