Panasonic S-LINK V User Manual page 151

Flexible wire-saving system
Hide thumbs Also See for S-LINK V:
Table of Contents

Advertisement

● Specifications
Designation
Model No.
Supply voltage
Current consumption
Allowable passing current
Number of connectable units
Operation mode
Transmission mode
indicator
Hexadecimal number
indicator
For setting and operation, use the address display on the CONTROL side, RUN / CHECK / CONFIG mode se-
Setting and operation
lector switch on the CONTROL side, SELECT keys (2 types) on the CONTROL side, and the ENTER key on the
CONTROL side.
Address display on
CONTROL side
Red LED × 6 [lights up when an error occurs, blinks when the error is canceled. (turns off when the ERROR
Error indicator
CLEAR key is pressed.)]
ERROR CLEAR key
Error output
Number of I/O points
For address setting, use the address display on the ADDRESS SET side, SELECT keys (2 types) on the AD-
Address setting
DRESS SET side, and ENTER key on the ADDRESS SET side.
Address display on
ADDRESS SET side
Input address indicator
Output address indicator
Orange LED × 16 [lights up when signals of 16 specified output addresses (the first address is specified) are
Data monitor indicator
turned ON.]
Data input validity
indicator
Data input VALID /
INVALID selector key
Lever switch × 16 incorporated
Data input switch
Using the data input VALID / INVALID selector key and the data input validity indicator, set the data input mode to
VALID or INVALID.
Ambient temperature
Ambient humidity
Noise immunity
Vibration resistance
10 to 150Hz frequency, 0.75mm amplitude or maximum acceleration 49m/s² in X, Y and Z directions for two hours each
Shock resistance
Weight
Accessory
500mA or less (excluding the connected unit drive power)
1 unit for 1 system (common to both master mode and slave mode)
Master mode and slave mode (Selected by mode selector switch)
Master mode: Controller function + I/O test function
Slave mode: I/O test function
Green LED (blinks when synchronization signal is input)
Orange LED (lights up when the address display is in the hexadecimal number display mode)
3 digit red LED (displays the number of connected nodes, recognized address, error address, etc.)
When an error occurs: Hi (24V)
When the error is canceled or when normal transmission is performed: Lo (0V)
• Maximum sink current: 100mA
• Residual current: 1.5V or less (at 100mA sink current)
3 digit red LED (displays the set address during address setting operation)
Green LED (lights up when the address display area displays the input address)
Orange LED (lights up when the address display area displays the output address)
Green LED (Lights up when data input is valid)
0 to +55ºC (No dew condensation), Storage: -20 to +75ºC
35 to 85% RH, Storage: 35 to 85% RH
Power line: 500Vp, 10ms cycle, 1µs pulse width (with noise simulator)
2
294m/s
acceleration (30G approx.) in X, Y and Z directions for three times each
Handy monitor
SL-VHM1
24V DC
%
+10
− 5
7A or less
Push-button type
16 input points, 16 output points
Push-button type
Approx. 380g
Strap: 1 pc.
Specifications