List Of I/O Units - Panasonic S-LINK V User Manual

Flexible wire-saving system
Hide thumbs Also See for S-LINK V:
Table of Contents

Advertisement

List of Models

List of I/O units

Designation
1-channel input unit
2-channel input unit
2-channel I/O mixed unit
1-channel output unit
2-channel output unit
4-channel input terminal
8-channel input terminal
16-channel input terminal
32-channel input terminal
4-channel output terminal
8-channel output terminal
16-channel output terminal
32-channel output terminal
4-channel connector
input unit
8-channel connector
input unit
4-channel e-CON type
connector input unit
8-channel e-CON type
connector input unit
4-channel connector
output unit
8-channel connector
output unit
4-channel e-CON type
connector output unit
8-channel e-CON type
connector output unit
16-channel MIL connec-
tor input unit
16-channel MIL connec-
tor output unit
Analogue input unit
Analogue output unit
4-channel relay output
terminal
8-channel relay output
terminal
8-channel input module
16-channel input module
8-channel output module
16-channel output module
Picking switch
Picking switch for shutter
158
Model No.
SL-VCH10
Input: 1 point
SL-VCH20
Input: 2 points
Input: 1 point
SL-VCH21
Output: 1 point
SL-VCH11
Output: 1 point
SL-VCH22
Output: 2 points
SL-VTB4
Input: 4 points
SL-VTB8
Input: 8 points
SL-VTB16
Input: 16 points
SL-VTB32
Input: 32 points
SL-VTBP4
Output: 4 points
SL-VTBP8
Output: 8 points
SL-VTBP16
Output: 16 points
SL-VTBP32
Output: 32 points
SL-VT4J
Input: 4 points
SL-VT8J
Input: 8 points
SL-VT4E
Output: 4 points
SL-VT8E
Output: 8 points
SL-VTP4J
Output: 4 points
SL-VTP8J
Output: 8 points
SL-VTP4E
Output: 4 points
SL-VTP8E
Output: 8 points
SL-VT16C1
Input: 16 points
SL-VTP16C1
Output: 16 points
SL-VTP16C1-S
SL-VTAD1
Input: 1 point
SL-VTDA1
Output: 1 point
SL-VTPR4
Output: 4 points
SL-VTPR8
Output: 8 points
SL-VM8
Input: 8 points
SL-VM16
Input: 16 points
SL-VMP8
Output: 8 points
SL-VMP16
Output: 16 points
This picking switch, which is designed to be mounted on a pipe, supports use of a
SL-VPK01
remote controller to set and check its address, lamp color, and other settings.
This picking switch, which is designed to be mounted on a pipe, supports use of a
SL-VPK01
remote controller to set and check its address, lamp color, and other settings.
This switch has a movable arm to which the shutter can be attached.
Description
Enables connection of 1 point of the input device.
Enables connection of 2 points of the input device.
Enables connection of 1 point of the input device and 1 point
of the output device.
Enables connection of 1 point of the output device.
Enables connection of 2 points of the output device.
These terminals enable connection of 4 points, 8 points, 16
points, or 32 points of the input device.
Since a power supply terminal for the input device is installed
for every 2 channels, simple wiring will be possible (excluding
the SL-VTB32).
These terminals enable connection of 4 points, 8 points, 16
points, or 32 points of the output device.
In addition, the output holding function is adopted for these
terminals.
For this reason, if the signal transmission line has a problem,
the output conditions just before occurrence of the problem will
be held.
Using the snap male connector (SL-CP□), up to 4 points or 8
points of the input device can be easily connected.
Using the e-CON compliant connector, up to 4 points or 8
points of the input device can be easily connected.
Using the snap male connector (SL-CP□), up to 4 points or 8
points of the output device can be easily connected.
For this reason, if the signal transmission line has a problem, the
output conditions just before occurrence of the problem will be held.
Using the e-CON compliant connector, up to 4 points or 8
points of the output device can be easily connected.
For this reason, if the signal transmission line has a problem, the
output conditions just before occurrence of the problem will be held.
Since the MIL connector can be used for connection, this small-
sized unit can connect up to 16 points of the intput device.
Since the MIL connector can be used for connection, this small-
sized unit can connect up to 16 points of the output device.
For this reason, if the signal transmission line has a problem,
the output conditions just before occurrence of the problem will
be held.
1 point of the analogue input device can be connected.
1 point of the analogue output device can be connected.
For this reason, if the signal transmission line has a problem,
the output conditions just before occurrence of the problem will
be held.
These relay output terminals have 4 or 8 output points. Relays
can be easily replaced. In addition, the output holding function
is adopted for these terminals. For this reason, if the signal
transmission line has a problem, the output conditions just be-
fore occurrence of the problem will be held.
These modules are the IC type that enables external installa-
tion of the address setting switches and indicators.
These modules therefore enable more flexible designing.

Advertisement