Panasonic S-LINK V User Manual page 140

Flexible wire-saving system
Hide thumbs Also See for S-LINK V:
Table of Contents

Advertisement

Specifications
● Specifications
Designation
Model No.
Supply voltage
Current consumption
Transmission specification
Transmission mode
Connecting method
Address settings
Input operation
On when the lever switch is tilted 15° or more or when the lever switch is pulled 1.6mm or more vertically (Note 1)
Number of I/O
Lamp
Transmission indicator
Ambient temperature
Ambient humidity
Noise immunity
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Mounting
Material
Cable
Weight
Accessory
NOTE
This product cannot be used in mode A (transmission mode).
Notes 1) Pulling load is less than 19.6N. Make sure that stress by forcible bend or pulling is not applied directly to the lever swich.
2) Selecting "green / blue" as the lamp color sets the lamp to two-stage indication mode.
<Two-stage indication mode>
● In two-stage indication mode, the lamp changes from lighting up in green to blinking in blue.
Overview of operation
• When the signal output from the signal transmission line to the lamp address ("output signal") turns ON, the lamp lights up in green.
• The lever switch input turns ON while the output signal is ON.
• When the output signal turns OFF, the lamp starts blinking in blue.
• When the output signal turns ON once more and then OFF, the lamp stops blinking in blue and turns OFF.
140
24V DC±10% (supplied from the S-LINK V controller or separate power supply)
24V DC line 25mA or less (when lamp is ON)
Input address (lever switch): 0 to 255
Output address (lamp): Select an offset of +32, +64, +128 or +256 for the input address
Set with the address setting remote controller SL-VAR1 (Ver.1.00 or later) (optional).
Lamp color (LED): Select from green, red, blue, and green / blue (Note 2).
When the output signal from the signal transmission line is ON: Lamp lights up.
When the output signal from the signal transmission line is OFF: Lamp turns OFF.
Green LED (blinks to indicate the synchronization signal transmission from S-LINK V controller)
0 to +55°C (No dew condensation allowed), Storage: -20 to +60°C
1,000V AC for one min. between all terminals connected together and enclosure
50MΩ, or more, with 250V DC megger between all terminals connected together and enclosure
10 to 150Hz frequency, 0.75mm in X, Y and Z directions for three times each
2
98m/s
acceleration in X, Y and Z directions for three times each
Product case: Polycarbonate, Lamp cover: Polycarbonate
Rear case: SGMCC (Steel plate treated with high corrosion resistant hot-dip plating)
Pipe mouting holder: SPCC (Cold-rolled steel plate)
2
0.5mm
4-core cabtyre cable, 0.15m long with connector (SL-CP2)
ø28 pipe mouting holder: 1 pc., Hexagon socket head cop screw for fixing holder [M6 (length: 15mm)]: 1 pc.
Picking switch
SL-VPK01
Based on S-LINK V protocol
B mode, C mode
Multi-drop connection
Lever input: 1 point, Lamp output: 1 point
35 to 85% RH, Storage: 35 to 85% RH
Power line: 500Vp-p (with noise simulator)
Mounted on pipe
Approx. 200g