● Input circuit diagrams and terminal layout drawing
<Current input>
Color code
+24V (Brown)
D (White)
G (Black)
0V (Blue)
S-LINK V system side
<Voltage input>
Color code
+24V (Brown)
D (White)
G (Black)
0V (Blue)
S-LINK V system side
<External synchronization input>
Color code
+24V (Brown)
D (White)
G (Black)
0V (Blue)
S-LINK V system side
*1
Non-voltage contact, NPN open-collector transistor or DC 2-wire output
• Current input: 9mA or less
• Operation voltage:
ON voltage: 17V or more [between input and +24V]
OFF voltage: 4V or less [between input and +24V]
• Input impedance: Approx. 3.3kΩ
When the shield cable is used, connect the shield wire to the frame ground etc. in the analogue output device side.
However, take care that there may be cases where it is better not to connect the shield wire depending on the
mounting conditions.
+24V (Brown)
Power supply circuit
Operational
amplifier
Approx. 220Ω
A/D
conversion
circuit
Approx.
30Ω
Internal circuit
Power supply circuit
Operational
amplifier
Approx. 900Ω
A/D
conversion
circuit
Approx.
100Ω
Internal circuit
Power supply circuit
+
External synchronization input
*1
-
Internal circuit
Input device side
Power supply circuit
D (White)
A/D
conversion
circuit
G (Black)
0V (Blue)
Analogue input
4 to 20mA range
COM.
Input device side
Analogue input
+1 to +5V range
0 to +10V range
-10 to +10V range
COM.
Input device side
Output circuit of
input device
Operational
amplifier
Analogue input
COM.
Shield
Specifications
Analogue output
device
High
Low
123