Fagor DDS Series Hardware Manual page 94

Table of Contents

Advertisement

  Power supplies
2.
94
DDS
HARDWARE
Ref.1912
· 94 ·
NOTE. When detecting an error, it will switch from any state 0, 1, 2 or 3
directly to state 4. From any of the states, it will switch to state 0 if a stop
occurs due to the NO READY state of any of the drives connected to the
power supply or because the power line has been disconnected or
because the emergency stop button has been pressed or because the
line voltage has dropped.
Follow this sequence to stop the system without having detected any errors:
 Disabling the drives; i.e. disable the Speed Enable of all the axes or the
System Speed Enable.
 Disconnecting the power line by opening the contactor
pressing the E-STOP button.