Fagor DDS Series Hardware Manual page 146

Table of Contents

Advertisement

  Drives
Derating depending on ambient temperature
3.
180
DDS
HARDWARE
Ref.1912
· 146 ·
Drive for an synchronous motor working as an axis
The following graphs show the maximum rms current in continuous duty
cycle (that is, the rated one) depending on the switching frequency of the
power transistors that the drives for synchronous motors can supply in a
temperature range between 5°C/41°F and 60°C/140°F.
NOTE. They can supply twice as much current for a maximum or 0.5 s,
and always in cycles longer than 10 s.
 For a switching frequency fc = 4 kHz
I (Arms)
6
In
4
2
0
35
40
45
50
(95)
(104) (113) (122) (131) (140)
F. H3/87
Current derating on ·ACD|CMC 1.08· drives for fc = 4 kHz.
I (Arms)
8
In
7
6
5
35
40
45
50
(95)
(104) (113) (122) (131) (140)
F. H3/88
Current derating on ·ACD|CMC 1.15· drives for fc = 4 kHz.
I (Arms)
13
In
12
11
10
35
40
45
50
(95)
(104) (113) (122) (131) (140)
F. H3/89
Current derating on ·ACD|CMC 1.25· drives for fc = 4 kHz.
I (Arms)
In
18
16
14
12
35
40
45
50
(95)
(104) (113) (122) (131) (140)
F. H3/90
Current derating on ·ACD|CMC 2.35· drives for fc = 4 kHz.
ACD|CMC 1.08
T ambient
° C
35
40
Tambient
45
°C (°F)
50
55
55
60
60
ACD|CMC 1.15
T ambient
° C
Tambient
°C (°F)
55
60
ACD|CMC 1.25
° C
Tambient
°C (°F)
55
60
ACD|CMC 2.35
T ambient
° C
35
40
Tambient
45
°C (°F)
50
55
55
60
60
In
° F
A
95
4.0
104
4.0
113
4.0
122
3.5
131
2.8
140
2.1
In
° F
A
35
95
7.5
40
104
7.5
45
113
7.5
50
122
7.0
55
131
6.3
60
140
5.5
T ambient
In
° F
A
35
95
12.5
40
104 12.5
45
113
12.5
50
122
11.9
55
131
11.2
60
140 10.5
In
° F
A
95
17.5
104 17.5
113
17.5
122 16.3
131 14.7
140 13.2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents