PS-65A module
Technical data
T. H2/1
Technical characteristics.
Line voltage
Line frequency
Mains power consumption (400 V AC)
Minimum connection cable section
Power bus voltage, VBUS rated
Rated (peak) output current
Rated (peak) output power
Power for the module control circuit
Consumption of the module control circuit itself
Internal Ballast resistance (power)
Energy pulse to be dissipated
Ballast circuit on/off
Minimum external Ballast resistance
Filter capacity
Energy stored in the capacitors
Maximum "SYSTEM OK" contact voltage
Maximum "SYSTEM OK" contact current
Width in mm | in
Approx. mass in kg | lb
Power dissipated at maximum load
·1· Depending on the rated operating power.
·2· For high temperatures, refer to derating graphs (power reduction graph).
T. H2/2
Ambient conditions and other characteristics.
Ambient temperature
·1·
Storage temperature
Maximum humidity
Maximum installation altitude
Operating vibration
Shipping vibration
Sealing
Protections
·1· For high temperatures, refer to derating graphs (power reduction graph).
Note that PS-65A power supplies admit a line voltage of up to 460 V AC.
PS-65A
3-ph, from 400 (1-10 %) V AC to 460 (1+10 %) V AC
48 ... 62 Hz
95 A
50 mm²
·1·
565 V DC / 650 V DC
120 A (360 A, 1 s)
·2·
65 kW (195 kW, 1 s)
24 V DC (between 21 V DC and 28 V DC)
1 A at 24 V DC (24 W)
9  (600 W)
·2·
36 kW (0.6 s)
768 V DC / 760 V DC
9 
940 µF, 900 V DC
0.5 C·V²
125 V AC, 150 V DC
1 A
117 | 4.61
9.9 | 22
275 W
PS-65A
0°C/45°C (32°F/113°F)
-25°C/+60°C (-13°F/+140°F)
< 90 % (non condensing at 45°C/113°F)
2 000 m (6 561 ft) above sea level
1 g
1.5 g
IP 2x
Over-voltage, heat-sink temperature, hardware error,
Ballast overload.
WARNING.